IndustriesServicesAbout & Contact

Product information

Back

Kicker

IONPURE® LX CEDI Modules

Continuous high-purity water without chemicals

The LX range can be used as a direct replacement for Suez’s E-Cell® EDI Modules with minimal retrofit efforts. The LX range is optimized to provide equal or better performance with IONPURE’S proven reliability.


Operating Environment
Installation should be indoors with no direct sunlight and should have a maximum ambient temperature of 113°F (45°C).


Quality Assurance Standards
CE marked. Each module is factory tested to meet strict industry standards and is manufactured in an ISO 9001 and ISO 14000 quality and environmental management system.

Product information

  • Feed Water Conductivity Equivalent (including CO2 and Silica): < 40 μS/cm
  • Feed Water Source: RO permeate
  • Temperature: 41° – 113°F (5 – 45°C) 41° – 140°F (5 – 60°C) – HWS Modules Only
  • Inlet Pressure: ≤ 100 psi (6.9 Bar)
  • Maximum Total Chlorine (as Cl2): < 0.02 ppm
  • Iron (Fe): < 0.01 ppm
  • Manganese (Mn): < 0.01 ppm
  • Sulfide (S2-): < 0.01 ppm
  • pH: 4 – 11
  • Total Hardness (as CaCO3): < 1.0 ppm
  • Dissolved Organics (TOC as C): < 0.5 ppm
  • Silica (as SiO2): < 1.0 ppm

Features & Benefits

  • Direct replacement for E-Cell MK1, MK2, and MK3 stacks
  • Generates mixed-bed quality deionized water without the use of chemicals
  • No need for acid/caustic, neutralization system or exchangable DI tanks
  • Continuous production instead of batch, with consistent quality
  • Double O-ring seal guarantees leak-free operation
  • Superior electrical isolation
  • 100 psi (7 bar), 113˚F (45˚C) continuous operation
  • Proprietary “all-filled” concentrating compartments eliminate recirculation pump and brine injection
  • Available for either industrial applications or pharmaceutical applications
  • atented instant hot and continuous operation up to 140° F (60° C) for HT replacements

Model series

  • Operating Parameters:
  • Recovery: 90-95%
  • Pressure Drop Range at Nominal Flow: 25-37 psi (1.7-2.5 bar), 20-30 psi (1.4-2.1 bar) – HWS Modules Only
  • Maximum Feed Temperature: 113˚F (45˚C)
  • DC Voltage: 0 – 3000
  • DC Amperage: 1.0 – 6.0, 1.0 – 10.0 – HWS Modules1
  • 10 – 4.5 assuming existing rectifier used
  • Product Water Quality:
  • Product Resistivity > 16 megohm-cm2
  • Silica (SiO2) Removal 90 – 99%, depending on feed condition
  • 2 Note: Actual performance may be determined using the IP-Pro projection software available from Ionpure.